If the roof specification wants one panel from eave to ridge, shortlist a roof-level outlet: ARC-T18 at the 18.5m catalog class, ARC-T25 or ARC-C25 at the 25m catalog class, with ARC-RF8 when you are also buying the line. If the specification allows a splice, keep the former on the ground and spend the money on the hoist and the seam, not on a taller lift. Panel length is not the catalog height. Load, chassis, and transport stay confirm on RFQ.
Contents
- The decision in one table
- Where the long panel actually fails
- What to measure before the class label
- Model shortlist
Use the height class as a screen, then draw the panel
A long panel is a flexible strip the moment it leaves the shear. The lift only earns its place when that strip can be aimed at the roof without a second bend. Write the panel length schedule next to the outlet height. Do not copy 18.5m or 25m into the length column.
One piece or a seam
Ask the architect which bays forbid a splice. Those bays set the outlet. The other bays can still be formed lower if the crew will accept two methods on one roof. Say that split in the RFQ so the quote does not assume every panel is the longest one.
Former, lift, and the person at the run-out
Three purchases sit in one sentence: the line makes the profile, the lift holds the line near the eave, and a named person supports the strip. If that third name is missing, the height class will not save the coating.

Reference photograph. It does not set a feed method.
Catalog classes you can put in the comparison
| Choice | Catalog figure you may cite | Use it for | Leave blank until RFQ or a site measure |
|---|---|---|---|
| ARC-T18 truck lift | 18.5m height class | Vehicle-mounted outlet screen | Platform load, chassis included, folded size: confirm on RFQ |
| ARC-T25 truck lift | 25m height class | Taller vehicle-mounted screen | Platform load, chassis, road envelope: confirm on RFQ |
| ARC-C25 crawler lift | 25m height class | Tracked moves between pads on one site | Ground bearing: measure on site. Low-bed arrival: confirm on RFQ |
| ARC-RF8 line | Sheet class 0.3–1.0mm | Profile family screen for roof and standing seam | Machine mass, power, tooling list: confirm on RFQ |
| Ground line plus hoist | No lift class | Roofs that allow a splice | Hoist and seam are the roof contractor’s method, not a catalog height |
Outlet datum
Measure to the point the panel must reach: slab, eave, or ridge. Write which. A catalog class that is taller than the eave is not proof the outlet clears the parapet. Measure the parapet on site.
Pads along the eave
Mark every setup. A 25m class that cannot travel from bay three to bay four is the wrong base even when the height looks right. Truck models move on the road envelope. Crawler models move on tracks and still arrive on a carrier.
Wind and the stop
Name who reads the wind and who may stop the shear. This page does not publish a wind number. Your method statement does.
The trade-off is carry distance against mass in the air
A ground line keeps the mechanic on the slab and hands a long carry to the roof crew. A roof-level outlet shortens that carry and puts former mass, coil side, and run-out on the lift interface. That interface is the constraint. Compare both routes on the same profile, the same thickness band, and the same handover sketch.

Reference photograph. It cannot prove panel length.
If the lifted route needs a chassis the destination will not register, drop it and price ARC-C25. If the ground route needs a splice the specification forbids, drop the ground route. Do not average the two into a slogan.
Failure modes that should kill the roof-level idea
The roof-level route may not fit when any of these are true.
- The run-out is a person grabbing a moving strip, and nobody will change that.
- The only pad is a slab with no bearing note. Measure on site before you ask for a load chart.
- The former you already own has no mass and no mounting outline.
- The panel must be flipped by hand at the eave.
- The job is people and materials under a ceiling. That is an ARC-F25 deck, not a forming lift.
Send this, then stop adding adjectives
- Outlet height and outreach to the eave you marked, plus the panel length that must arrive there
- Roof slope, parapet, and the geometry of each handover
- Profile, material, thickness, coil width, and feed side
- Wind rule and the name of the person who stops the line
- Ground or floor under the first pad
- Access route from the gate to that pad
- Outrigger or track footprint you hope the pad can take
- Destination country and port
- Chassis included, local, or unsure, and the transport assumption
- Container question, only if someone has already raised 40HQ
- Voltage at the pad and who owns the controls
- Documents the destination reviewer will ask to see
Open one model and send the sketch
Send the work height, the site pad, the destination, the transport assumption, the handover zone, and the floor or ground note. The signed schedule is project-specific. Editorial images do not set a load or a price.
Shortlist: ARC-T18 for the 18.5m truck class, ARC-T25 or ARC-C25 for the 25m class, and ARC-RF8 if the line is in the same purchase. Request a quote, WhatsApp +86 15515922444, or leelogly120@gmail.com. The HSE work-at-height guidance is a Great Britain reference for the people at the eave. It does not rate these models.

Reference photograph. It is not a measured travel state.
Does 18.5m or 25m mean the panel can be that long?
No. Those are catalog height classes. Send the length schedule with the profile.
Can the former and the lift be one RFQ?
Yes. Name ARC-RF8 and the lift together so the mount is reviewed once.
We already own the former. What do you need?
Mass, outline, coil side, and power. Unknown is acceptable. A guessed kilogram is not.
Truck or crawler first?
Public road between roofs: ARC-T18 or ARC-T25. One site, track moves: ARC-C25.
